Why 3 dB Doubles Power but 6 dB Doubles Voltage
Power ratios use 10 log10 and voltage ratios across the same resistance use 20 log10, because P = V²/R. Doubling power is +3.01 dB; doubling voltage is +6.02 dB, which is a fourfold increase in power.
Engineer’s note: Power doubles every 3 dB; voltage doubles every 6 dB. In a link budget meeting where the PA output is quoted as power and the ADC full scale as voltage, people mix the two up and end up off by a factor of two. Keep them clearly separate in your head.
For practitioners
The decibel is defined for power. The voltage form, 20 log10, is not a second definition. It is the power definition rewritten for one special case: two voltages measured across the same resistance. Once you see that, the 3 dB and 6 dB rules follow, and you can tell when the 20 log10 form stops being valid.
The decibel is a power ratio
A ratio between two powers, expressed in decibels, is:
Nothing in this definition mentions voltage, current or impedance. A ratio of 2 in power is 10 log10(2) = 3.01 dB. A ratio of 10 is 10 dB. A ratio of 0.5 is −3.01 dB. Any dB figure you read on a gain, loss, isolation or rejection spec is a statement about power, even when the instrument actually sensed a voltage.
Where the 20 comes from
In a resistance R, the dissipated power is P = V²/R. Substitute that into the definition for two voltages V1 and V2 across the same R:
The R cancels only because it is the same in the numerator and the denominator. The square becomes a factor of 2 in front of the logarithm, because log(x²) = 2 log(x). That factor of 2 is the whole story: 10 becomes 20.
The same argument works for current, since P = I²R, so a current ratio through the same resistance is also 20 log10(I2/I1).
The inverse forms are:
- Power ratio from dB: P2/P1 = 10^(dB/10)
- Voltage ratio from dB, same R: V2/V1 = 10^(dB/20)
The doubling numbers: 3.01 dB and 6.02 dB
Apply each form to a ratio of 2:
- Power doubled: 10 log10(2) = 3.01 dB
- Voltage doubled, same R: 20 log10(2) = 6.02 dB
The 6.02 dB is not a separate kind of decibel. It equals 10 log10(4), because doubling the voltage across a fixed resistance quadruples the power. The dB value describes one physical change. The 3 dB and 6 dB rules just describe that change from the power side or from the voltage side.
Going down works the same way. Halving the power is −3.01 dB. Halving the voltage across the same resistance is −6.02 dB, which leaves one quarter of the power.
For a ratio of 10, power gives 10 dB and voltage gives 20 dB. A tenfold voltage ratio across the same R is a hundredfold power ratio, and 10 log10(100) = 20 dB.
On a log-scaled ratio axis, both relationships are straight lines that start at 0 dB at a ratio of 1. The voltage line has exactly twice the slope of the power line. At x = 2 the lines sit at 3.01 dB and 6.02 dB. At x = 10 they sit at 10 dB and 20 dB.
The opposite question comes up often: what voltage ratio gives 3 dB? The answer is 10^(3.01/20) = √2 ≈ 1.414. To double the power into a fixed load, you raise the voltage by about 41 percent, not 100 percent.
A round "3 dB" is also not exactly double. 10^0.3 ≈ 1.995 in power. The error is small enough to ignore in link budgets, but it is the reason careful tables quote 3.01 dB and 6.02 dB.
Worked example: 1 V to 2 V across 50 Ω
Take an RMS voltage of 1 V across 50 Ω, then raise it to 2 V across the same 50 Ω.
- P1 = 1² / 50 = 0.02 W = 20 mW
- P2 = 2² / 50 = 0.08 W = 80 mW
- Power ratio: 80 / 20 = 4, so 10 log10(4) = 6.02 dB
- Voltage ratio: 2 / 1 = 2, so 20 log10(2) = 6.02 dB
In absolute terms, 20 mW is 10 log10(20) = 13.01 dBm and 80 mW is 10 log10(80) = 19.03 dBm. The difference is 6.02 dB, the same answer by a third route. Use the dBm to watts converter to check conversions like these.
When 20 log10 gives the wrong answer
If the two voltages are across different resistances, R no longer cancels. The full expression is:
The last term is the correction. With equal resistances it is zero. With a 50 Ω input and a 200 Ω output, the term is 10 log10(50/200) = −6.02 dB. In that case a stage that doubles the voltage delivers the same power at its output as at its input, so the power gain is 0 dB, while 20 log10 of the voltage ratio reports +6.02 dB.
Where each form shows up in RF work
- Gain, loss and power levels (dB, dBm): 10 log10 of a power ratio. These add directly along a chain, as covered in dB and dBm in a signal chain.
- S-parameters: |S21| in dB is 20 log10|S21|. S-parameters are ratios of normalized waves whose squared magnitudes are powers, so 20 log10 of the wave ratio equals 10 log10 of the power ratio.
- Reflection coefficient: return loss is −20 log10|Γ| for the same reason. Γ is an amplitude ratio at one reference impedance.
- dBV and dBµV: 20 log10 of a voltage relative to 1 V or 1 µV. Turning these into dBm needs the impedance.
The rule in every case is the same. Use 10 log10 for anything proportional to power. Use 20 log10 for anything proportional to the square root of power, such as voltage, current or wave amplitude, at a fixed impedance.
In plain words · for students and beginners
3 dB versus 6 dB in plain words
An everyday picture: the side and area of a square
Think of a square tile. If you double the length of its side, the area does not double. It grows four times, because area is side times side. Voltage and power behave the same way. Power goes up as voltage times voltage (divided by the resistance, which means how strongly the load resists current). So doubling the voltage gives four times the power.
The decibel (dB) always counts power. Doubling power is about 3 dB. Four times the power is about 6 dB. So doubling the voltage is also about 6 dB.
Where the picture breaks down: a square has no resistance. The voltage rule only works when both voltages sit across the same resistance. If the resistance changes, the square picture no longer tells you the power.
The same example in simple steps
Two identical circuits drive the same resistor R.
- Left circuit: 1 V. Call the power 1 unit.
- Right circuit: 2 V. The power is 2 × 2 = 4 units.
- Voltage went up 2 times: 20 log10(2) = +6.02 dB.
- Power went up 4 times: 10 log10(4) = +6.02 dB.
- Both give the same number, because they describe the same change.
If you only want twice the power (+3.01 dB), the voltage only needs to rise by the square root of 2, which is about 1.414 times.
With real numbers across 50 Ω: 1 V gives 20 mW and 2 V gives 80 mW. That is four times the power, and the difference is 6.02 dB.
Mistakes beginners make
- Using 10 log10 for a voltage ratio. That gives 3 dB for double the voltage, which is wrong. Voltage ratios need 20 log10.
- Thinking 3 dB and 6 dB are different kinds of dB. There is only one kind. The 20 log10 form is just the power formula written in terms of voltage.
- Ignoring the resistance. If the two voltages are across different resistances, the 20 log10 shortcut does not give the power change.
- Expecting double voltage to mean double power. It means four times the power.
Remember
- Power ratio: 10 log10. Double the power is +3.01 dB, ten times is 10 dB.
- Voltage ratio across the same resistance: 20 log10. Double the voltage is +6.02 dB, ten times is 20 dB.
- +6.02 dB from doubling the voltage means four times the power, because P = V²/R.
Related pages on RF View
Frequently asked questions
Why is doubling voltage 6 dB and not 3 dB?
Power across a fixed resistance goes as voltage squared, P = V²/R. Doubling the voltage multiplies the power by four, and 10 log10(4) = 6.02 dB, which is the same as 20 log10(2).
When should I use 20 log10 instead of 10 log10?
Use 10 log10 for power ratios. Use 20 log10 for voltage or current ratios, but only when both voltages are across the same resistance. Then both forms give the same dB value.
How much voltage gain gives 3 dB?
A 3.01 dB step is a voltage ratio of the square root of 2, about 1.414, across the same resistance. That doubles the power.
Is a 3 dB step exactly double the power?
Not exactly. Doubling power is 3.0103 dB, so a round 3 dB step is a power ratio of 10^0.3, about 1.995. For most engineering work the difference doesn't matter.