dBm, dBW and dBmV: Picking the Right Reference Level
dBW is dBm minus 30, so 1 W is 30 dBm and 0 dBW. dBmV is a voltage level: in 50 ohm dBmV = dBm + 46.99, and in 75 ohm dBmV = dBm + 48.75.
Engineer’s note: Phone and base-station RF runs on dBm in 50 ohms, but when you work with CATV tuner designers, dBmV in 75 ohms turns up. Converting between them means accounting for the impedance difference too, so agree on one unit at the very start of the collaboration.
For practitioners
A decibel is a ratio. It only becomes an absolute level once you fix what it is a ratio to. The letters after "dB" name that reference: m for one milliwatt, W for one watt, mV for one millivolt rms. Two of these units are power levels and one is a voltage level. That difference matters more than the letters suggest.
Two power references: dBm and dBW
Both power units use the 10 log rule, since they compare powers:
One watt is 1000 mW, and 10 log10(1000) = 30. So the two scales differ by a fixed offset:
That gives 1 W = 30 dBm = 0 dBW, and 1 mW = 0 dBm = −30 dBW. The offset holds in any system at any frequency, because both units measure the same thing. Only the zero point moves.
Which one to use is a matter of scale. Handset and bench work lives between a few tens of dBm and well below −100 dBm, and milliwatts are the natural unit there. Transmitter and link budget work with large powers often uses dBW, so the numbers stay small and positive. A dB of gain or loss is the same dB on either scale, so a chain calculation works the same way in both.
dBmV is a voltage level
dBmV compares a voltage, so it uses the 20 log rule:
On its own, a dBmV number says nothing about power. 0 dBmV means 1 mV rms across something. How much power that is depends on what the something is. To get power you need the impedance:
Work this into decibels and you get a general link between dBmV and dBm for a resistive impedance Z in ohms:
The 30 comes from moving between watts and milliwatts. The 60 dB from the millivolt reference (20 log10(1000)) combines with the 10 log10(Z) term. For the two common system impedances:
- 50 ohm: 10 log10(50) = 16.99, so dBmV = dBm + 46.99
- 75 ohm: 10 log10(75) = 18.75, so dBmV = dBm + 48.75
You can check the 50 ohm figure directly. 0 dBm in 50 ohm is V = √(0.001 × 50) = 0.2236 V rms, or 223.6 mV. 20 log10(223.6) = 46.99 dBmV. For 75 ohm, start from the voltage side: 1 mV rms across 75 ohm is 1e-6 / 75 = 1.333e-8 W, which is −48.75 dBm. So 0 dBmV in 75 ohm is −48.75 dBm.
The two offsets differ by 1.76 dB. If you use the wrong one, every result is off by that amount. The error is small enough to look reasonable, so it rarely gets noticed.
The three scales side by side in 50 ohm
In a 50 ohm system all three units line up with fixed offsets. The figure shows three reference points: 1 mW, 1 W and 10 W.
Reading across: 1 mW is −30 dBW, 0 dBm and 46.99 dBmV. 1 W is 0 dBW, +30 dBm and 76.99 dBmV. 10 W is +10 dBW, +40 dBm and 86.99 dBmV. The dBW and dBm columns would sit in the same place in a 75 ohm system. Only the dBmV column would move, by 1.76 dB.
Worked example: 10 W into 50 ohm
A transmitter delivers 10 W into a 50 ohm load. Express it in all three units.
dBm: 10 log10(10 W / 1 mW) = 10 log10(10 000) = 40 dBm.
dBW: 40 − 30 = +10 dBW. As a check, 10 log10(10 W / 1 W) = 10 dBW.
Voltage: V = √(P × Z) = √(10 × 50) = √500 = 22.36 V rms.
dBmV: 20 log10(22 360 mV / 1 mV) = 86.99 dBmV. The shortcut gives the same: 40 + 46.99 = 86.99 dBmV.
If the same 22.36 V rms appeared across 75 ohm, the power would be 500 / 75 = 6.67 W, about 38.24 dBm. The dBmV value stays the same and the power changes. That is the whole point of keeping the impedance in view.
Why each field uses its own reference
RF power work uses dBm or dBW because power is what the designer cares about. Amplifier gain, cable loss and attenuator values are power ratios, so absolute power levels and dB gains add directly. Power sensors measure power. A power level also stays meaningful at an interface where impedance is defined differently on either side, because power is what actually gets delivered.
75 ohm cable distribution systems quote levels in dBmV. The whole plant runs at one fixed impedance, so a voltage level maps one-to-one to a power level and nothing is lost. Levels at taps and outlets are typically a few tens of dBmV, so the numbers stay small and easy to handle.
Converting between the two worlds needs only the impedance-specific offset. Keep the 75 ohm offset (48.75) for cable work and the 50 ohm offset (46.99) for bench and radio work, and write down which one you used.
In plain words · for students and beginners
dBm, dBW and dBmV in plain words
An everyday analogy
Think of a height. "Ten metres above the floor" and "ten metres above the street" are different heights. The number is the same and the starting point is different. dBm and dBW are the same kind of measure (power) taken from two starting points. One starts at a milliwatt and one starts at a watt. Moving between them is always the same step of 30.
dBmV is different. It measures voltage, the electrical "push", and not power. Think of water pressure in a pipe. The same pressure moves a lot of water through a wide pipe and only a little through a narrow one. Voltage is like the pressure. Impedance (the opposition a circuit puts up to current, measured in ohms) is like the pipe width. You can't know the flow, or the power, from the pressure alone.
The analogy has a limit. In a real pipe a wider pipe always means more flow. In a circuit a higher impedance means less power for the same voltage, because power is voltage squared divided by impedance.
The drawing shows this. Put 1 mV across a 50 ohm resistor and you get 20 nW (nanowatts, billionths of a watt), which is −46.99 dBm. Put the same 1 mV across a 75 ohm resistor and you get 13.33 nW, which is −48.75 dBm. The voltage is the same and the power is different.
The worked example, step by step
A transmitter puts out 10 W into 50 ohm.
- Turn watts into milliwatts: 10 W = 10 000 mW.
- Take 10 × log10 of that: 10 × 4 = 40 dBm.
- For dBW, subtract 30: 40 − 30 = 10 dBW.
- For dBmV in a 50 ohm system, add 46.99: 40 + 46.99 = 86.99 dBmV.
That last number is the same as saying there are 22.36 volts across the 50 ohm load.
Mistakes beginners make
- Using 10 log for dBmV. Voltage levels use 20 log, because power goes with voltage squared.
- Forgetting the impedance. A dBmV number from a 75 ohm cable system can't be turned into dBm with the 50 ohm offset.
- Thinking dBm and dBW measure different things. They both measure power and differ only by 30.
- Mixing up rms and peak voltage. The 1 mV in dBmV is an rms value (rms is the "effective" value that gives the same heating as a steady DC voltage).
Remember
- dBW = dBm − 30, so 1 W is 30 dBm and 0 dBW.
- dBmV is a voltage. You need the impedance to turn it into power.
- In 50 ohm add 46.99 to dBm to get dBmV. In 75 ohm add 48.75.
Related pages on RF View
Frequently asked questions
How do I convert dBm to dBW?
Subtract 30. A watt is a thousand milliwatts, and 10 log10(1000) is 30 dB, so 30 dBm is 0 dBW and 0 dBm is -30 dBW.
What is 0 dBm in dBmV?
It depends on the impedance. In a 50 ohm system 0 dBm is 0.2236 V rms, which is 46.99 dBmV. In a 75 ohm system 0 dBm is 48.75 dBmV.
Why does dBmV need an impedance to convert to dBm?
dBmV measures voltage and dBm measures power. Power is V squared divided by R, so the same voltage gives different power in different resistances. You need the impedance to get from one to the other.
Why do cable TV systems use dBmV instead of dBm?
Cable systems are built around one fixed 75 ohm impedance, so a voltage level always maps to the same power. Quoting levels in dBmV is the convention in that field, and with the impedance fixed it carries the same information as a power level.