Why You Cannot Measure Z0 With an Ohmmeter

At DC a coax line is just two wires, so an ohmmeter reads the load plus the conductor resistance and never Z0. Z0 shows up for only one round trip, 2l/vp. That is 10 ns for 1 m at vp = 2.0e8 m/s, when a 1 V step from 50 Ω launches 0.5 V.

Engineer’s note: Every so often a new engineer probes a 50 ohm line with a multimeter and asks why it reads open. Z0 is the ratio of voltage to current for a wave travelling down the line, not a DC resistance you can probe. To measure it you need a TDR or a VNA. Don't lose sight of that basic point.

For practitioners

What the ohmmeter actually sees

An ohmmeter pushes a small DC current through whatever is connected and measures the voltage that results. At DC a coaxial line is just two wires. Its series inductance acts as a short and its shunt capacitance acts as an open, so neither one affects the reading. What is left is the far-end load in series with the loop DC resistance of the center conductor and the shield.

Three cases follow:

  • Open far end: the meter reads open.
  • Shorted far end: the meter reads close to 0 Ω. The small residual is the loop resistance.
  • Resistor at the far end: the meter reads that resistor plus the loop resistance.

None of these readings is Z0. The meter cannot tell a 50 Ω coax from a 75 Ω coax or from two lengths of hookup wire, as long as the load on the end is the same.

Ohmmeter at DCΩohmmeterreading: open (∞)50 Ω coaxopen endat DC: two wires,the meter sees only the loadStep from pulse generatorRs = 50 ΩV = 1 V × 50/(50+50)= 0.5 V50 Ω coaxopen endpulse generatorVs = 1 Vfor the first 10 nsthe generator sees 50 Ω
An ohmmeter on an open 50 Ω coax reads open, while a step from a 50 Ω generator first sees Z0 and launches a 0.5 V wave. Concept drawing.

Z0 is a wave ratio, not a resistance

Z0 is the ratio of voltage to current in a single wave travelling in one direction along the line. For a lossless line it depends only on the inductance L and capacitance C per unit length:

Z0=LCZ_0 = \sqrt{\frac{L}{C}}

No power is dissipated in that ratio. Z0 describes how the line relates V and I while a wave is moving and has not yet reached anything that sends energy back. Once a reflected wave exists, the voltage and current at the input are sums of forward and backward waves. Their ratio is no longer Z0 unless the load equals Z0.

A DC reading is the extreme case of a steady state. In effect, the meter waits through an unlimited number of round trips. Every reflection has returned and settled, and the line's own impedance has dropped out of the result. Only the load is left.

A step into the line: Z0 for one round trip

Now replace the ohmmeter with a step source that has open-circuit voltage Vs and internal resistance Rs. At t = 0 the leading edge enters the line. At that moment the source has no information about the far end. It can only drive the line itself, which looks like a resistor of value Z0. The launched voltage is set by a simple divider:

V1=VsZ0Z0+RsV_1 = V_s \frac{Z_0}{Z_0 + R_s}

This wave travels to the far end at vp. There it meets the load ZL and reflects with

Γ=ZL−Z0ZL+Z0\Gamma = \frac{Z_L - Z_0}{Z_L + Z_0}

Γ = +1 for an open, Γ = −1 for a short and Γ = 0 for ZL = Z0. The reflected wave reaches the input after one round trip:

trt=2lvpt_{\text{rt}} = \frac{2l}{v_p}

The ratio of voltage to current at the input equals Z0 only between t = 0 and t = 2l/vp. After that, the source sees the load through the line. Once the reflections have settled, the input sits at the DC value set by ZL and Rs.

That window is the reason Z0 can be measured in the time domain and not with a DC meter. Time-domain reflectometry uses exactly this circuit: a fast step, a known source resistance and an oscilloscope at the input. The plateau before the first reflection gives Z0 through the divider formula.

Worked example: 1 m of 50 Ω coax with an open end

The values are Vs = 1 V, Rs = 50 Ω, Z0 = 50 Ω, l = 1 m and vp = 2.0e8 m/s. The far end is open.

  1. Launched voltage. V1 = 1 × 50 / (50 + 50) = 0.5 V. For now the source can only treat the line as a 50 Ω resistor, so the source and line form a 1:1 divider.
  2. Round-trip time. t_rt = 2 × 1 / 2.0e8 = 10 ns.
  3. Reflection at the open end. Γ = +1, so the 0.5 V wave reflects as a 0.5 V wave travelling back toward the source.
  4. Input after 10 ns. The input voltage becomes 0.5 + 0.5 = 1 V. That is the DC value: an open load draws no current, so there is no drop across Rs. The returning wave meets Rs = 50 Ω, which equals Z0. The source reflection coefficient is therefore zero and the wave is absorbed. Nothing bounces again, and the input stays at 1 V from 10 ns onward.

The same line with other loads:

  • Shorted end, Γ = −1: the input drops from 0.5 V to 0.5 − 0.5 = 0 V at 10 ns.
  • Matched 50 Ω end, Γ = 0: the input stays at 0.5 V indefinitely. This is the only case where the input still looks like 50 Ω after the round trip. The reason is the load resistor, not the line.

For these three loads the ohmmeter reads open, close to 0 Ω and about 50 Ω. The step shows 0.5 V, which means 50 Ω, during the first 10 ns in all three cases.

An ohmmeter reading of about 50 Ω on a coax assembly tells you a 50 Ω resistor is at the far end. It says nothing about whether the cable itself is 50 Ω.

What this means on the bench

A DC continuity check finds opens and shorts. It does not check impedance. To see Z0 in the time domain, the edge has to rise well within the 2l/vp window. A 1 m line gives 10 ns. Shorter lines and PCB traces give proportionally less time, so they need faster edges.

A network analyzer gets the same information in the frequency domain through Γ. The VSWR and reflection coefficient page explains how Γ turns into the numbers you read. When the line is part of a fixture, port extension and de-embedding shows how to remove its effect.

In plain words · for students and beginners

Characteristic impedance in plain words

An everyday analogy

Picture a long rope tied to a wall. Flick your end and a wave runs down the rope. In the first instant, how hard the rope pushes back depends only on the rope itself: how heavy it is and how tight it is. It does not depend on the wall, because the wave has not reached the wall yet. When the wave bounces off the wall and comes back, you start to feel the wall.

If you pull slowly and steadily instead, you feel only the wall, never the rope's "wave push." An ohmmeter does the slow, steady pull. It uses DC, a current that never changes. That is why it reports only what is at the far end.

The analogy breaks down in two places. A rope wave is slow enough to watch, while a wave on coax covers 1 m in 5 ns. Also, Z0 is not a force. It is the ratio of voltage to current in a moving wave.

The same example, step by step

0510152000.51.01.2time (ns)input voltage (V)round trip 2l/vp= 2 × 1 / 2.0e8 = 10 nssource sees Z0 = 50 Ω,V = 1 × 50/(50+50) = 0.5 Vreflection returns, Γ = +1:0.5 + 0.5 = 1 V,source sees the load (open)
Input voltage of a 1 m, 50 Ω line with an open far end, driven by a 1 V step from a 50 Ω source: 0.5 V until the 10 ns round trip, then 1 V. Computed from the formula.
  • A 1 V step comes from a source with 50 Ω inside it (Rs, the source resistance). It drives 1 m of 50 Ω coax with nothing connected at the far end.
  • At first the source "sees" only the cable, which acts like a 50 Ω resistor. The voltage splits in half: 1 × 50/(50 + 50) = 0.5 V.
  • The wave travels to the end and back. The trip takes 2 × 1 / 2.0e8 = 10 ns. Here vp is the speed of the wave in the cable.
  • The open end sends the wave back unchanged. Γ, the reflection coefficient, measures how much of the wave comes back and with what sign. At an open end, Γ = +1.
  • At 10 ns the returning 0.5 V adds to the 0.5 V already there, so the input reads 1 V. That is the same value an ohmmeter-style DC test would give.

Mistakes beginners make

  • Expecting a meter to read 50 Ω on a 50 Ω cable. It reads open, short or whatever is on the far end.
  • Thinking a 50 Ω reading proves the cable is good. It proves only that a 50 Ω resistor is on the end.
  • Confusing loop resistance with Z0. Loop resistance is the small DC resistance of the copper. Z0 is a property of the wave.
  • Using a step that is too slow. If the edge takes longer than the round trip, the reflection returns before the plateau has formed, and you never see Z0.

Remember

  • At DC a line is just two wires, so an ohmmeter sees only the load.
  • Z0 shows up only until the first reflection returns, which takes 2l/vp.
  • 1 V from 50 Ω into 50 Ω launches 0.5 V. An open end doubles it to 1 V after one round trip.

Frequently asked questions

Why does my multimeter not read 50 ohms on a 50 ohm coax cable?

At DC the cable is just two wires. Its inductance acts as a short and its capacitance as an open. The meter reads the far-end load plus the loop resistance of the conductors, so an open cable reads open and a shorted cable reads close to 0 Ω.

If the ohmmeter reads 50 ohms, is the cable 50 ohm?

No. A reading of about 50 Ω means a 50 Ω resistor is at the far end. A line of any characteristic impedance with the same resistor on the end gives the same reading.

How long does a step see the characteristic impedance of a line?

For one round trip, 2l/vp, until the first reflection from the far end gets back to the source. For a 1 m line with vp = 2.0e8 m/s, that is 10 ns.

How can Z0 be measured if not with an ohmmeter?

Drive the line with a fast step from a known source resistance and look at the input voltage before the first reflection returns. The launched voltage is Vs·Z0/(Z0 + Rs), so Z0 follows from that plateau.

References and further reading