Quarter-Wave and Half-Wave Lines: Inverter and Repeater

A lossless λ/4 line gives Zin = Z0²/ZL, so a 100 Ω load on a 50 Ω line looks like 25 Ω, while a λ/2 line gives Zin = ZL. Both rules hold only near the design frequency: at 2f0 a quarter-wave line is a half-wave line and repeats the load.

Engineer’s note: A quarter-wave line turns an open into a short, which makes it very handy in bias tee design. Remember it only works near one frequency, though. At 2f0 the same line is a half wave, a repeater, and the filtering effect disappears completely, so on its own it's a poor tool for suppressing the second harmonic.

For practitioners

Two line lengths turn the general transmission-line formula into one-line rules. A quarter-wave line inverts the load about Z0. A half-wave line passes the load through unchanged. These rules show up in matching sections, bias feeds, stub filters and harmonic traps. Both hold only at, or near, one frequency.

The input-impedance formula at 90° and 180°

For a lossless line of characteristic impedance Z0 and length l, terminated in ZL:

Zin=Z0ZL+jZ0tan⁡βlZ0+jZLtan⁡βlZ_{\text{in}} = Z_0 \frac{Z_L + j Z_0 \tan \beta l}{Z_0 + j Z_L \tan \beta l}

Here β = 2π/λ is the phase constant, so βl is the electrical length in radians or degrees.

Quarter wave, l = λ/4, βl = 90°. tan βl goes to infinity. Divide the numerator and the denominator by j tan βl and let the tangent grow. The ZL and Z0 terms that are not multiplied by the tangent drop out:

Zin=Z0Z0ZL=Z02ZLZ_{\text{in}} = Z_0 \frac{Z_0}{Z_L} = \frac{Z_0^2}{Z_L}

Half wave, l = λ/2, βl = 180°. tan βl = 0. Both tangent terms vanish:

Zin=Z0ZLZ0=ZLZ_{\text{in}} = Z_0 \frac{Z_L}{Z_0} = Z_L

The half-wave result does not depend on Z0. A λ/2 line of any impedance repeats the load at its design frequency. The quarter-wave result depends on Z0 squared, and that is what makes it useful as a transformer.

The inversion also maps reactances. A load of +jX becomes Z0²/(jX) = −jZ0²/X, so inductive becomes capacitive. The extreme cases follow from the same rule. An ideal quarter-wave line turns a short into an open and an open into a short.

The same result from round-trip phase

A second way to see it uses the reflected wave instead of impedances. On a lossless line the reflected wave goes down the line and comes back, so it covers the length twice:

Γin=ΓL e−j2βl\Gamma_{\text{in}} = \Gamma_L \, e^{-j 2 \beta l}

Only the phase changes. The magnitude |Γ| stays the same along a lossless line.

  • λ/4 line: 2βl = 180°, so Γin = −ΓL. Flipping the sign of Γ is the same as inverting the normalized impedance: if z = (1 + Γ)/(1 − Γ), then replacing Γ with −Γ gives 1/z. Denormalizing, Zin = Z0 · (Z0/ZL) = Z0²/ZL.
  • λ/2 line: 2βl = 360°, so Γin = ΓL, and Zin = ZL.

On the Smith chart this is a rotation about the centre at constant |Γ|. A quarter wave is half a turn, which lands on the point diametrically opposite. A half wave is one full turn, which comes back to the start. The Smith chart basics page covers the rotation in more detail.

Worked example: 100 Ω on a 50 Ω line

Take Z0 = 50 Ω and ZL = 100 Ω.

Load reflection coefficient: ΓL = (100 − 50)/(100 + 50) = 1/3.

Through λ/4:

  • Formula: Zin = 50²/100 = 2500/100 = 25 Ω.
  • Phase: Γin = −1/3, so Zin = 50 · (1 − 1/3)/(1 + 1/3) = 50 · (2/3)/(4/3) = 25 Ω.

Through λ/2:

  • Formula: Zin = 100 Ω.
  • Phase: Γin = +1/3, so Zin = 50 · (4/3)/(2/3) = 100 Ω.

Both methods agree. The mismatch is the same in both cases, |Γ| = 1/3. The quarter wave does not fix the mismatch. It moves it to the other side of 50 Ω. In between, the impedance is complex. At βl = 45°, tan βl = 1 and the formula gives Zin = 40 − j30 Ω, so |Zin| = 50 Ω.

0255075100110|Zin| (Ω)0°45°90°135°180°Electrical length βl (degrees)00.511.52f/f0 (line is λ/4 long at f0)0°: ZL = 100 Ωrepeater: ZL = 100 Ω (2f0)inverter: Z0²/ZL = 25 Ω (f0)|Zin|, lossless lineZ0 = 50 Ω, ZL = 100 Ω
Input impedance magnitude of a lossless 50 Ω line with a 100 Ω load versus electrical length and normalized frequency, showing the quarter-wave inverter and half-wave repeater points. Computed from the formula.

The plot shows |Zin| as the electrical length goes from 0° to 180°. It starts at 100 Ω, falls to the inverter point of 25 Ω at 90°, and climbs back to the repeater point of 100 Ω at 180°. The second axis gives the same sweep as frequency, f/f0 from 0 to 2, for a line that is λ/4 long at f0.

The quarter-wave transformer

To match a real load to a real source impedance, choose the section impedance Z1 so that Z1²/ZL equals the target:

Z1=Z0 ZLZ_1 = \sqrt{Z_0 \, Z_L}

For ZL = 100 Ω to 50 Ω, Z1 = sqrt(50 × 100) = 70.7 Ω. At the design frequency the input sees 70.7²/100 = 50 Ω. This works directly for real loads. A complex load first needs a length of line or a reactive element that makes it real, and then the quarter-wave section transforms that real value. The matching networks page compares this approach with lumped L, Pi and T networks.

Frequency dependence and loss

Electrical length scales with frequency. On a non-dispersive TEM line, βl = 90° · f/f0 for a line that is λ/4 long at f0. Away from f0 the tangent is finite. The inversion is only approximate, and a quarter-wave transformer no longer gives exactly 50 Ω. The further the frequency moves from f0, the larger the error.

At 2f0 the same piece of line is λ/2 long, so it repeats the load instead of inverting it. This has a practical side. A shorted λ/4 stub that looks open at f0 looks shorted again at 2f0. That can be used as a second-harmonic trap, or it can cause one by accident.

A quarter-wave bias feed or stub is designed at one frequency. At twice that frequency it is a half-wave line and behaves as a repeater, not an inverter. Check the harmonics before you assume the stub is invisible.

Loss changes the endpoints. With attenuation the formula uses tanh(γl) in place of j tan(βl), and |Γ| shrinks on every pass. A transformed short becomes a large but finite impedance. A transformed open becomes a small but nonzero one. How far a real stub falls short of an ideal open or short depends on the line loss. The VSWR and reflection coefficient page explains how |Γ| relates to mismatch loss.

In plain words · for students and beginners

Quarter-wave and half-wave lines in plain words

An everyday analogy

Shout at a wall and the echo comes back to you. The delay depends on how far away the wall is. On a cable, the "echo" is the reflected wave, the part of the signal that bounces back from the load (the thing at the far end). If the cable is a quarter of a wavelength long (one wavelength is the distance the wave travels in one cycle), the echo comes back exactly half a cycle late. It arrives upside down. If the cable is half a wavelength long, the echo comes back one full cycle late. It looks just like it left.

Upside down means the load looks inverted: high becomes low, and low becomes high. Same shape means the load looks unchanged.

Where the analogy breaks down: a real echo only gets quieter. On a cable, the timing (phase) of the echo decides what impedance (the voltage-to-current ratio, in ohms) you see at the input. Also, the "quarter wavelength" is only a quarter at one frequency. Change the frequency and the cable is a different fraction of a wavelength.

The same example, step by step

Zin = 50²/100 = 25 Ω(inverter)Γin = −ΓL(180° round trip)λ/4 line, βl = 90°Z0 = 50 ΩZL = 100 ΩZin = 100 Ω(repeater)Γin = ΓL(360° round trip)λ/2 line, βl = 180°Z0 = 50 ΩZL = 100 Ω
A 100 Ω load on a 50 Ω line looks like 25 Ω through a quarter-wave section (inverter) and stays 100 Ω through a half-wave section (repeater). Concept drawing.
  1. The cable has Z0 = 50 Ω. Z0 is the characteristic impedance, a property set by the cable's construction.
  2. The load is 100 Ω.
  3. Quarter-wave cable (90°): Zin = 50 × 50 / 100 = 2500 / 100 = 25 Ω. The 100 Ω load now looks like 25 Ω. That is the inverter in the top drawing. The echo has turned around, Γin = −ΓL. Γ (gamma) is the reflection coefficient, the size and sign of the echo.
  4. Half-wave cable (180°): Zin = 100 Ω. The load looks the same as it is. That is the repeater in the bottom drawing, with Γin = ΓL.
  5. To make 100 Ω look like 50 Ω, use a quarter-wave piece of 70.7 Ω cable, because 70.7 × 70.7 / 100 ≈ 50.

Mistakes beginners make

  • Thinking a quarter-wave line removes the mismatch. Without a 70.7 Ω section, 100 Ω only becomes 25 Ω, which is just as far off.
  • Forgetting frequency. At twice the design frequency, a quarter-wave line is a half-wave line, and it stops inverting.
  • Using the length in free space. The wavelength inside a cable or a PCB trace is shorter than in air, so measure the length in electrical terms.
  • Expecting a perfect open from a shorted stub. With real loss you get a large impedance, not an infinite one.

Remember

  • λ/4 line: Zin = Z0²/ZL. It inverts the load.
  • λ/2 line: Zin = ZL. It repeats the load.
  • Both rules hold only near the design frequency, and at 2f0 a λ/4 line acts like a λ/2 line.

Frequently asked questions

Why does a quarter-wave line invert impedance?

At βl = 90° the tangent term in the input-impedance formula goes to infinity, and the formula reduces to Zin = Z0²/ZL. Seen through the reflection coefficient, the reflected wave picks up 180° on its round trip, so Γin = −ΓL.

What impedance does a half-wave line present?

A lossless half-wave line (βl = 180°) presents the load impedance unchanged, Zin = ZL, whatever Z0 is. The reflected wave travels a full 360° round trip and comes back in the same phase.

What impedance do I need for a quarter-wave transformer from 100 Ω to 50 Ω?

The section impedance is the geometric mean, Z1 = sqrt(50 × 100) = 70.7 Ω. This gives an exact match only at the frequency where the section is λ/4 long.

Does a quarter-wave stub still invert at the second harmonic?

No. On a TEM line, a line that is λ/4 long at f0 is λ/2 long at 2f0, so at 2f0 it repeats the load. A shorted λ/4 stub that looks open at f0 looks like a short again at 2f0.

References and further reading