Characteristic Impedance Derived From L and C Per Unit Length
Z0 is set by inductance and capacitance per metre, not by length: Z0 = sqrt((R + jωL)/(G + jωC)), which reduces to sqrt(L/C) for a lossless line. With L = 250 nH/m and C = 100 pF/m, L/C = 2500 Ω² and Z0 = 50 Ω.
Engineer’s note: On paper Z0 is set by the ratio of L and C. On a real production board, L and C keep moving with etching tolerance on the line width and the spread in prepreg thickness. Even if the simulation hits 50 ohms, measure the first bare boards on a TDR before anything else and confirm the real impedance landed on target.
For practitioners
Every RF engineer uses "50 Ω" daily, yet the number is not a resistor anywhere on the board. It comes from two physical properties of the line: how much magnetic energy it stores per metre and how much electric energy it stores per metre. This page builds the line from small sections, derives Z0, and works one example to a 50 Ω result.
The line as a ladder of short sections
A transmission line can be modelled as a chain of short sections, each Δz long. Every section has a series resistance R·Δz and inductance L·Δz, followed by a shunt conductance G·Δz and capacitance C·Δz. R, L, G and C are all given per unit length: Ω/m, H/m, S/m and F/m.
- R: loss in the conductors
- L: magnetic energy stored by the current
- G: leakage through the dielectric
- C: electric energy stored by the voltage between the conductors
The drawing shows three identical sections. V(z) and I(z) are at the left input. V(z+Δz) and I(z+Δz) are at the node at the end of the first section, one Δz further along. The right-hand port of the three-section chain sits at z + 3Δz. The model only becomes exact in the limit Δz → 0, with infinitely many infinitesimal sections. The useful point is that every section is identical, because R, L, G and C are properties per metre, not properties of the whole line.
Telegrapher's equations
Apply Kirchhoff's laws across one section. The voltage drops across the series branch, and current is lost through the shunt branch. Divide by Δz and let Δz → 0:
Differentiate the first equation and substitute the second. Both voltage and current then obey the same wave equation:
Here α is the attenuation in Np/m and β is the phase constant in rad/m. The general solution is the sum of a forward wave and a backward wave: V(z) = V0+ e^(−γz) + V0− e^(+γz).
Deriving Z0
Put the forward wave V0+ e^(−γz) into dV/dz = −(R + jωL)I. Differentiating gives −γ V0+ e^(−γz), so the forward current is I0+ e^(−γz) with I0+ = γ V0+ / (R + jωL). The ratio of voltage to current in that single wave is:
The ratio is the same at every z, because the e^(−γz) factor cancels. That is the formal reason length does not appear. Z0 is the V/I ratio of one wave travelling in one direction. It is not a resistance you could locate anywhere along the line.
You can reach the same result without the wave equation. Take a semi-infinite ladder with input impedance Zin. Adding one more section in front leaves an infinite ladder, so Zin cannot change:
Rearranging and letting Δz → 0 gives Zin² = (R + jωL)/(G + jωC), which is Z0 again. Section length drops out entirely. Only the ratio of the series impedance per metre to the shunt admittance per metre is left.
The lossless case: Z0 = sqrt(L/C)
With R = G = 0 the jω terms cancel:
This result does not depend on frequency, and Z0 is purely real. For a real line where ωL ≫ R and ωC ≫ G, the general expression approaches the same value, which is why sqrt(L/C) is the working formula at RF. The same assumption gives β = ω·sqrt(LC) and a phase velocity vp = 1/sqrt(LC).
The geometry sets L and C. Wider traces or thinner dielectrics raise C and lower L, so they pull Z0 down. Narrower traces or thicker dielectrics push it up. Raising the dielectric constant raises C, which lowers Z0 and also slows the wave. The microstrip impedance calculator turns that geometry into Z0 directly.
Worked example: 250 nH/m and 100 pF/m
Take a lossless line with L = 250 nH/m and C = 100 pF/m.
- Ratio: L/C = (250e-9 H/m)/(100e-12 F/m) = 2500 Ω². The per-metre units cancel, and H/F reduces to Ω².
- Impedance: Z0 = sqrt(2500 Ω²) = 50 Ω.
- Product: LC = 250e-9 × 100e-12 = 2.5e-17 s²/m².
- Phase velocity: vp = 1/sqrt(2.5e-17 s²/m²) = 1/(5e-9 s/m) = 2.0e8 m/s, about 0.67 times the speed of light.
As a check, the two results recover the inputs. L = Z0/vp = 50/2.0e8 = 250 nH/m, and C = 1/(Z0·vp) = 1/(50 × 2.0e8) = 100 pF/m. Z0 and vp together carry exactly the same information as L and C. This is the usual route from a target impedance and a known dielectric to a trace geometry, as in microstrip width for 50 Ω on FR4.
Note the square root. To double Z0 from 50 Ω to 100 Ω, L/C has to rise four times, from 2500 Ω² to 10000 Ω². Small geometry errors therefore move Z0 less than they move L or C.
In plain words · for students and beginners
Characteristic impedance in plain words
An everyday picture
Think of a long rope shaken at one end. How hard you must push for a given hand speed depends on the rope's tension and its weight per metre, not on how long the rope is. A transmission line works the same way. Inductance per metre (L) is like the rope's weight: it resists changes in current. Capacitance per metre (C) is like its springiness: it soaks up voltage. Together they fix how much current flows for a given voltage in a travelling wave. That ratio is Z0.
The picture breaks down in one place. A rope has no "ohms", and nothing in a perfect line turns energy into heat. Z0 is not a resistor that gets hot. It only describes how voltage and current relate inside a moving wave.
The example, step by step
- Start with L = 250 nH/m. "nH" means nanohenry, 0.000000001 henry, so L = 250e-9 H/m.
- Start with C = 100 pF/m. "pF" means picofarad, 0.000000000001 farad, so C = 100e-12 F/m.
- Divide: 250e-9 / 100e-12 = 2500. The unit is ohms squared (Ω²).
- Take the square root: sqrt(2500) = 50. So Z0 = 50 Ω.
- Bonus: wave speed vp = 1/sqrt(L × C) = 2.0e8 m/s, about two thirds of the speed of light.
The plot shows Z0 rising with L/C along a square-root curve. The marked point at 2500 Ω² sits at 50 Ω, and the curve reaches 100 Ω at 10000 Ω². Length is nowhere on the plot, because only L and C per metre set Z0.
Mistakes beginners make
- Thinking a longer cable has a higher Z0. It does not. Ten centimetres or ten metres of the same cable have the same Z0. A longer cable has more loss, which is a different thing.
- Trying to measure Z0 with a multimeter. A multimeter uses DC (steady current). Between the two conductors it reads open, and along one conductor it reads almost zero. Neither number is Z0.
- Mixing up nano and pico. One nH is 1000 times bigger than one pF in the powers of ten. Getting this wrong moves L/C by a factor of 1000 and Z0 by about 32.
- Forgetting the square root. Doubling C does not halve Z0. It divides Z0 by about 1.41.
Remember
- Z0 = sqrt(L/C) for a lossless line, using L and C per metre.
- Z0 is the voltage-to-current ratio of one travelling wave, not a resistor.
- 250 nH/m and 100 pF/m give 50 Ω and a wave speed of 2.0e8 m/s.
Related pages on RF View
Frequently asked questions
Why does characteristic impedance not depend on cable length?
Z0 is the voltage-to-current ratio of a single wave travelling in one direction, and that ratio is fixed by the inductance and capacitance per metre. Length only matters once a reflected wave exists, which changes the input impedance but not Z0.
What is the formula for characteristic impedance from L and C?
For a lossless line Z0 = sqrt(L/C), with L in H/m and C in F/m. The general form with losses is Z0 = sqrt((R + jωL)/(G + jωC)).
What L and C per metre give a 50 ohm line?
Any pair with L/C = 2500 Ω² gives 50 Ω. One example is L = 250 nH/m and C = 100 pF/m, which also gives a phase velocity of 2.0e8 m/s.
Can I measure Z0 with an ohmmeter?
No. Z0 is not a resistance located anywhere on the line, so a DC meter reads only the conductor resistance or the open between conductors. Z0 shows up only as the ratio of voltage to current in a travelling wave.