10 log vs 20 log: Which Decibel Formula to Use When

Use 10 log10 for power and power spectral density, and 20 log10 for voltage, current, field and |S21|. A 20 log voltage ratio equals the power ratio only when R1 = R2. Otherwise add 10 log10(R1/R2), which is −1.76 dB for 1 V on 75 Ω vs 50 Ω.

Engineer’s note: On a VNA, S21 in dB uses 20 log because S-parameters are ratios of voltage waves, while power on a spectrum analyzer uses 10 log. Different instruments and quantities use different bases. Don't memorize the formulas mechanically; just ask whether the quantity is a voltage or a power, and you won't get it wrong.

For practitioners

The rule in one sentence

If the quantity is a power, or proportional to power like power spectral density, the decibel value is 10 log10 of the ratio. If it is a root-power (field) quantity, such as voltage, current, electric field strength or the magnitude of an S-parameter, the decibel value is 20 log10 of the ratio.

XdB=10log⁡10(P2P1)(power, PSD)X_{\text{dB}} = 10 \log_{10}\left(\frac{P_2}{P_1}\right) \quad \text{(power, PSD)}
XdB=20log⁡10(V2V1)(voltage, current, field, ∣S21∣)X_{\text{dB}} = 20 \log_{10}\left(\frac{V_2}{V_1}\right) \quad \text{(voltage, current, field, } |S_{21}|\text{)}

That is why |S21| in dB is 20 log10|S21|, not 10 log10|S21|. The two forms are built so that one physical change gives one decibel number. A 10 dB step is a factor of 10 in power and a factor of 3.16 in voltage across the same impedance, because 3.16² ≈ 10. A 20 dB step is a factor of 100 in power and 10 in voltage.

The unit suffix tells you which form was used. dBm and dBW are 10 log of power relative to 1 mW and 1 W. dBm/Hz is a power spectral density, so it also uses 10 log. dBV, dBmV and dBµV are 20 log of voltage relative to 1 V, 1 mV and 1 µV.

Why field quantities get 20 log

In a resistance, power goes as the square of the amplitude: P = V²/R, or P = I²R. The log of a square doubles the coefficient:

10log⁡10(V22V12)=20log⁡10(V2V1)10 \log_{10}\left(\frac{V_2^2}{V_1^2}\right) = 20 \log_{10}\left(\frac{V_2}{V_1}\right)

So 20 log is not a separate definition. It is the 10 log power rule applied to the square of an amplitude. Electric field strength works the same way, because the power density of a wave goes as E² for a given wave impedance.

S-parameters follow the same logic. S21 is the ratio of the transmitted wave amplitude to the incident wave amplitude, both normalized to the port reference impedance. The matching power ratio is |S21|². Since 10 log10|S21|² = 20 log10|S21|, the dB value of S21 is already a power ratio at the reference impedance. You don't have to choose between the two forms. They give the same number.

The impedance term you cannot drop

The step from voltage to power assumes both voltages sit across the same resistance. In general, take rms voltage V1 across R1 and rms voltage V2 across R2. Then P1 = V1²/R1, P2 = V2²/R2, and

10log⁡10P2P1=20log⁡10V2V1+10log⁡10R1R210 \log_{10}\frac{P_2}{P_1} = 20 \log_{10}\frac{V_2}{V_1} + 10 \log_{10}\frac{R_1}{R_2}

When R1 = R2 the last term is zero, and the voltage ratio in dB equals the power ratio in dB. When the impedances differ, the two are different numbers, so you have to say which one you mean. For current the correction flips: P = I²R gives a term of +10 log10(R2/R1).

What is the ratio of?power,power spectral densityvoltage, current,electric field, |S21|10 log10(P2/P1)20 log10(V2/V1)same impedance at bothpoints (R1 = R2)?yesnoequals powerratio in dBadd 10 log10(R1/R2)to get power ratiocurrent: add 10 log10(R2/R1)Note: 10 dB = ×10 power = ×3.16 voltage (same impedance)
Decision flow for choosing 10 log10 or 20 log10 and applying the impedance correction, which flips to R2/R1 for current. Concept drawing.

The flow chart shows the decision. Power and power spectral density go straight to 10 log10(P2/P1). Voltage, current, field and |S21| go to 20 log10(V2/V1). Then one check: is the impedance the same at both points? If it is, the result is the power ratio. If it isn't, add 10 log10(R1/R2) to get the power ratio.

Worked example: same voltage, different power

Put 1 V rms across 50 Ω and 1 V rms across 75 Ω.

  • 50 Ω: P = (1 V)² / 50 Ω = 20 mW, which is 10 log10(20) = 13.01 dBm.
  • 75 Ω: P = (1 V)² / 75 Ω = 13.3 mW, which is 10 log10(13.3) = 11.25 dBm.

The voltage ratio is 20 log10(1/1) = 0 dB. The power ratio from the general formula is 0 + 10 log10(50/75) = −1.76 dB. As a check, 10 log10(13.3/20) = −1.76 dB, and 11.25 − 13.01 = −1.76 dB. All three agree.

A dBµV or dBV reading is a voltage. To turn it into dBm you need the impedance it was measured across. If you convert a reading from a 75 Ω system with 50 Ω math, the result reads 1.76 dB too high.

Where the rule trips people up

Impedance-transforming networks. An ideal lossless 50 Ω to 75 Ω transformer passes all the power, so the power ratio is 0 dB. The voltage still changes. Solving 0 = 20 log10(V2/V1) + 10 log10(50/75) gives a voltage step of +1.76 dB. If you call that a "gain" without saying it's a voltage gain, the reader will assume it's a power gain, and there isn't one.

Voltage gain of stages with unequal impedances. A stage with a high-impedance input driving a 50 Ω load can have a large voltage gain in dB. That number is not its power gain. Either label it as voltage gain or add the 10 log10(R1/R2) term.

Spreadsheets and scripts. Applying 10 log to a voltage ratio gives half the correct dB value. Applying 20 log to a power ratio gives double. Both mistakes look reasonable at a glance, so test each formula with a known factor of 10.

Mixing units in one sum. dBm and dBV can't be added or subtracted directly. Convert both to the same kind of quantity first, at a stated impedance. The signal-chain dB and dBm page covers the bookkeeping. The return loss vs insertion loss page applies the same 20 log rule to reflection and transmission magnitudes.

In plain words · for students and beginners

10 log vs 20 log in plain words

An everyday picture

Think of a square tile. Voltage is like the length of one side. Power is like the area. If you make the side twice as long, the area grows four times. Decibels always count the area, which is the power. So when you only know the side (the voltage), you need a bigger multiplier, 20 instead of 10, to land on the same decibel number.

Where the picture breaks down: in a circuit, power also depends on the resistance the voltage pushes into. Resistance is how hard the circuit resists current. The same push into a harder load gives less current and less power. A tile has nothing like that, so the tile picture only works when both voltages sit across the same resistance.

The same example, step by step

Case 1: 50 ohm load1 V rms50 ohmP = (1 V)^2 / 50 ohm= 20 mWCase 2: 75 ohm load1 V rms75 ohmP = (1 V)^2 / 75 ohm= 13.3 mWvoltage ratio20 log10(1/1) = 0 dBpower ratio10 log10(13.3/20)= 10 log10(50/75)= −1.76 dBsame voltage, less power
The same 1 V rms across 50 ohm and across 75 ohm gives a 0 dB voltage ratio but a −1.76 dB power ratio. Concept drawing.
  1. Put 1 volt across a 50 ohm resistor. Power = 1 × 1 ÷ 50 = 0.020 W, which is 20 mW.
  2. Put 1 volt across a 75 ohm resistor. Power = 1 × 1 ÷ 75 = 0.0133 W, which is 13.3 mW.
  3. Compare the voltages: 20 log10(1/1) = 0 dB. The voltages are equal.
  4. Compare the powers: 10 log10(13.3/20) = −1.76 dB. The 75 ohm resistor gets less power.
  5. Shortcut: 10 log10(50/75) gives the same −1.76 dB without working out the powers.

So equal voltages don't mean equal power when the resistances differ.

Mistakes beginners make

  • Using 10 log on a voltage. Your answer comes out half of what it should be. A voltage that grows 10 times is 20 dB, not 10 dB.
  • Assuming 0 dB of voltage means 0 dB of power. That's only true when the resistance is the same at both points.
  • Converting a voltage reading to dBm without the resistance. dBm means power compared with 1 milliwatt. You can't get power from voltage until you know the resistance.
  • Adding dBm to dBV. One is power and the other is voltage. Convert them to the same kind first.

Remember

  • Power-type quantities take 10 log. Voltage, current, field and |S21| take 20 log.
  • 10 dB is 10 times the power and 3.16 times the voltage, as long as the resistance doesn't change.
  • If the resistances differ, add 10 log10(R1/R2) to the voltage dB to get the power dB.

Frequently asked questions

When do I use 10 log and when do I use 20 log for decibels?

Use 10 log10 of the ratio for power-type quantities such as power and power spectral density. Use 20 log10 for root-power quantities such as voltage, current, electric field and S-parameter magnitudes.

Why is S21 in dB equal to 20 log10|S21|?

S21 is a ratio of wave amplitudes, not powers. The power ratio is |S21|², and 10 log10|S21|² is the same number as 20 log10|S21|.

Does a 0 dB voltage ratio mean the power is the same?

Only if both voltages are across the same impedance. With 1 V rms across 50 Ω and across 75 Ω, the voltage ratio is 0 dB, but the power ratio is 10 log10(50/75) = −1.76 dB.

How much is 10 dB in power and in voltage?

A 10 dB change is a factor of 10 in power. Across the same impedance it is a factor of 3.16 in voltage, because 3.16 squared is about 10.

References and further reading